PharmaLectures.com

Courses › Pharma training by country › From Egyptian, Gulf and MENA GMP to EU GMP: the gap list, and how to close it

From Egyptian, Gulf and MENA GMP to EU GMP: the gap list, and how to close it

Your team walks into a European inspection with every EudraLex gap already closed.

  • 10 audio modulesthree lengths each
  • 1 h 40 min to 8 h 20 minbriefing to expanded
  • Workbook, transcript, certificateand a recorded quiz per module
  • Egypt, Gulf and MENA companieswho it is written for

Why this training matters

A European inspector asks for the batch release file. Your local procedure never recorded a step that EudraLex Volume 4 expects, so the file has a hole. The finding is written, the shipment sits in your warehouse, and your team rewrites procedures against a deadline.

What changes after this course

The team sets each local procedure beside EudraLex Volume 4 and closes the gap before the inspector finds it. You hold a certificate for each learner, a recorded questionnaire result for each module, and a training record per person that you can put on the table.

Watch the pitch

3:43 on how an audio course is bought, listened to and recorded. Full screen, one click.

Watch the pitch3:43, full screen, one click

What this course gives your people

Regulatory staff stop guessing. They put each local procedure beside the matching clause of EudraLex Volume 4 and mark where it falls short. When a rule from your national authority and Chapter 1 point different ways, the manager sees the gap, ranks it, and decides on the spot how to close it before the inspection.

Production and engineering managers check cleanroom plans against Annex 1 and computerised systems against Annex 11 before a contractor is hired. Operators fill in batch records the way Chapter 4 expects, with dated corrections and both signatures. A deviation under Chapter 5 gets written once, with the decision and the owner named.

Laboratory heads open an out-of-specification investigation that follows Chapter 6 and stands up to questions. Procurement writes the technical agreement that Chapter 7 calls for, and visits a supplier with a list of what to check. When a defect report comes in, the team follows Chapter 8 and knows when the competent authority must be told.

Quality Assurance prepares the inspection room: the batch release file shaped around Annex 16, the training records Chapter 2 asks for, and one named person ready to answer each question. Afterwards the team writes the response to any observations without a round of blame.

Who needs this training

  • Quality Assurance Manager

    Your European importer's Qualified Person asks what proof sits behind each batch. You answer with a release file built around Annex 16, with every signature and test result where they expect it.

  • Production Head

    You plan a line upgrade and need to know whether Annex 1 applies before the contractor draws the first plan. The modules give you the checks to make, so you avoid rework after the inspection.

  • Quality Control Laboratory Head

    An analyst reports an out-of-specification result at the end of the day. You know the first steps, the records to protect, and what Annex 11 expects of the instrument software behind the number.

  • Training and Development Manager

    An inspector asks for the file of one operator. You hand over qualification, job description and signed training records that all match, as Chapter 2 expects.

  • Procurement and Supply Chain Manager

    A contract manufacturer is due for a visit and the agreement is two pages old. You walk in with the Chapter 7 checks and the responsibilities written down.

Roles: Quality assurance and Qualified Person, Quality control and laboratory, Production and engineering

Businesses: every kind of pharma company

Countries: Egypt, Gulf and MENA

Selling into: Europe and the UK

Courses are in English. Other languages on request.

After this course your people can

  1. Compare a local procedure with the matching EudraLex Volume 4 clause and write the gap into a ranked list.
  2. Assign an owner to each quality decision in your Pharmaceutical Quality System, as Chapter 1 expects.
  3. Assemble a Chapter 2 training file for one operator that an inspector can read in a minute.
  4. Correct a batch record entry so the original stays readable and the change is dated and signed.
  5. Open an out-of-specification investigation with the first steps and records that Chapter 6 expects.
  6. Draft a technical agreement that divides quality duties between you and a contract manufacturer under Chapter 7.
  7. Write a response plan to inspection observations with an owner and a date for each action.

What the company gets

  • Your export files stop stalling on basic gaps that a European inspector can find in a single document.
  • The facility holds one ranked gap list against EudraLex Volume 4, with an owner and a date beside each item.
  • Upgrade money goes to the Annex 1 and Annex 11 work that matters, not to rework after a finding.
  • Human resources and Quality Assurance hold a training record for each person and a certificate for each learner, ready for the inspector.

The evidence: questionnaire, training record, certificate

EU GMP Chapter 2, section 2.11, and 21 CFR 211.25 both ask for training that is documented and shown to work. This is what each learner leaves behind.

A recorded questionnaire per module

Every one of the 10 modules ends with a multiple-choice questionnaire. The result is recorded per person with a timestamp, whichever of the three lengths the person listened to.

A per-person training record

The export lists each learner, each module, the result and the date, which is the training record EU GMP Chapter 2 and 21 CFR 211.25 ask you to keep and the first thing an inspector asks for.

A certificate per learner

Name, company, course, hours, the guideline version taught and the date. It documents in-company training; it is not a professional qualification or an accreditation.

Your pass mark, your rule

There is no fixed pass mark. Your quality or human-resources manager decides what counts as passed and when a module is retaken, exactly as your training procedure says.

Delivered within 72 hours of payment, with the workbook, the full transcript and a source for every fact in the audio.

How long it takes, by who is listening

Nobody spends a day in a classroom. Every module exists in three lengths; a person takes the length their role needs, and every length ends with the same recorded questionnaire, so the training record is complete either way.

Briefing1 h 40 min10 min a module, for executives, sales and anyone who must know the rules, not run them
Standard4 h 10 min25 min a module, for regulatory, quality and business-development staff
Expanded8 h 20 min50 min a module, for technical staff who run the procedure day to day
Who takes this courseLengthTotal time
Quality assurance and Qualified PersonStandard4 h 10 min
Production and engineeringStandard4 h 10 min
Quality control and laboratoryStandard4 h 10 min

Course outline: 10 modules

10 modules. Under each title are the three things the listener can do afterwards; the audio itself runs 10 to 50 minutes depending on the length chosen.

  1. 1Map your local procedures to EudraLex Volume 4 and list every gap

    • How to set a local rule beside its EudraLex Volume 4 clause and see at once where it falls short.
    • Why a gap list ranked by inspection risk gets budget approved when a long list of differences does not.
    • What to do when your national regulator's rule and EudraLex Volume 4 point in different directions.
  2. 2Build a quality system that passes Chapter 1 inspection questions

    • Why your Quality Manual can read well and still fail the Chapter 1 test of a working quality system.
    • How to name who owns each quality decision, so no task sits between two departments.
    • The management review record that shows an inspector your quality system is checked, not just written.
  3. 3Keep personnel training records that pass a Chapter 2 inspection

    • The training file an inspector is likely to ask for, kept ready to hand over in one minute.
    • How to show that a job description, a training plan and a signed record agree with each other.
    • What to do when an operator has done a task before the training record says they were trained.
  4. 4Upgrade premises and equipment to meet Annex 1 and Annex 11

    • Why a layout that worked for local inspections can draw a cross-contamination finding under Chapter 3.
    • How to check your cleanroom plans against Annex 1 before any money is spent on building.
    • When a spreadsheet or instrument software counts as a computerised system under Annex 11.
  5. 5Write batch records that satisfy Chapter 4 documentation rules

    • How to write a batch record so the operator, the checker and the auditor all read the same story.
    • Why a missing second signature or an undated correction turns a good record into a finding.
    • What to do when an entry is wrong and the original must stay readable.
  6. 6Run production and close Chapter 5 deviations on the floor

    • The deviation report that states what happened, what it touched and who decided, on one page.
    • What to do when a packaging component fails inspection and the line is already waiting.
    • How to catch mix-ups at line clearance with a check your operators finish in minutes.
  7. 7Run a Chapter 6 laboratory and investigate out-of-specification results

    • How to write a sampling plan that an inspector can follow from the warehouse to the lab bench.
    • What to do in the first hour after an out-of-specification result so the investigation holds up.
    • Why a retest without a documented reason becomes a data integrity finding, and how to avoid it.
  8. 8Qualify suppliers and manage contract manufacturers under Chapter 7

    • How to write a technical agreement that tells you and your contract manufacturer who does what.
    • The questions to ask on a supplier visit before you sign, so the audit report supports your decision.
    • Why you stay responsible for a batch made by someone else, and how to prove you kept control.
  9. 9Handle product defects and market recalls under Chapter 8

    • What to do when a defect report arrives from a European distributor on a Friday afternoon.
    • How to log a complaint so the trend shows before the second and third report arrive.
    • When a quality defect must go to the competent authority, and who in your team makes that call.
  10. 10Answer inspector questions and present evidence in a European inspection

    • How to answer the question that was asked, in plain words, and then stop talking.
    • The documents to have ready in the inspection room, so no one leaves to search for a file.
    • What goes into the response plan when the inspection ends with observations.
The founders

One of us was inspected. The other one pays for the training.

Every claim below is sourced on the about page: the medicines register, the Lithuanian Pharmaceutical Union board list, the university directory.

Justina Krukonytė-Racz

Justina Krukonytė-Racz

Co-founder. Licensed pharmacist.

GDPResponsible PersonWarehouse & logistics

Licensed pharmacist. Responsible Person at Tamro (PHOENIX group), where she led the GDP set-up of the distribution centre.

The Responsible Person is the named person the regulator holds accountable for every pallet that leaves the building.

She writes the modules around the procedures a GDP inspection checks. Board member of Lithuanian Pharmaceutical Union.

Listed in the Lithuanian medicines register as Pharmacist.

Prof. Ben Racz

Prof. Ben Racz

Co-founder. Builds the platform and is responsible for delivery, records and pricing.

Platform & deliveryQuantitative researchCarnegie Mellon

He was Professor of the Practice at the College of Engineering at Carnegie Mellon University, where he taught Advanced Quantitative Finance and Algorithmic Trading to MSc students.

He is the founder and Managing Director of Algorithmic Sciences, a scientific research and consulting firm. Earlier he co-founded a data-driven growth consultancy, a data-science based wholesale trading company and an information security firm.

More about Ben at benracz.com

Questions about this course

Is there a certificate?

Yes. Every learner who finishes the course receives a certificate in their own name, and every module ends with a recorded multiple-choice questionnaire, so the certificate sits on top of a per-person training record. The certificate documents in-company training; it is not a professional qualification or an accreditation, and your quality or human-resources manager sets the pass mark and decides when a module is retaken.

How long does the course take?

10 modules, each in three lengths: a 10-minute briefing, a 25-minute standard run and a 50-minute expanded walk-through. The whole course takes 1 h 40 min in the briefing length and 8 h 20 min in the expanded length. People take the length their role needs, and every length ends with the same recorded questionnaire, so the training record is complete either way.

Who should take this course?

It is written for Egypt, Gulf and MENA companies. Owners, managers and sales staff hear the briefing length, regulatory, quality and business-development staff take the standard run, and the people who run the procedure every day get the expanded version. One licence covers one named person on this course for a year, so the same title can be rolled out across a whole team at once.

Is this training accepted as a GMP training record by an auditor?

EU GMP Chapter 2 and 21 CFR 211.25 require documented, effective training, and that is what the course produces: a recorded multiple-choice result per module and per person, a certificate per learner and a transcript of what was taught. No provider can promise acceptance by a specific inspector; the record is built to answer what inspectors ask for, and your quality manager decides the pass mark.

How is it delivered and how fast?

The course arrives as audio files with a companion workbook, a full transcript and the questionnaire per module, within 72 hours of your payment arriving. You host the files on your own system or share them as you like; there is no platform to log into and no learner management system to set up. The free sample module arrives on request, before any purchase.

What does it cost per learner?

The list price is 9 euros per module, per learner, per year, so this course is 90 euros for one person for twelve months. The price per learner falls as more people take the same course: 10 learners pay 10 percent less and the discount keeps growing to 50 percent at 1000 learners. Type a number on the price panel and the yearly total appears.

Get this course for your team

One licence is one person on this course for a year. All three lengths, the workbook, the certificate and the training record are included in every purchase. Pick how many people, add it to the cart, and you have an invoice in your inbox.

Free sample module

Hear one full module before you spend a cent. Send your company and the role you want trained, and a complete sample module comes back with its workbook and transcript.

Connect on WhatsApp

or email [email protected], or ask for a written quote for your team