PharmaLectures.com

Courses › GMP, GDP, quality and compliance › ICH Q3D elemental impurities and residual solvents for API and finished dose

ICH Q3D elemental impurities and residual solvents for API and finished dose

Your impurity file answers the inspector before a batch ever sits in quarantine.

ICH Q3D is the international guideline on elemental impurities in medicines, such as lead, cadmium, arsenic, mercury and catalyst metals. It sets permitted daily exposures by route of administration and requires a risk-based approach in three steps: identify possible sources, evaluate them against the limits, and summarize and document the assessment. It applies to new finished drug products and to new products containing existing active substances, and it includes limits for skin application. Residual solvents follow the companion guideline ICH Q3C. Your team gets both, for APIs and finished doses.

  • 6 audio modulesthree lengths each
  • 1 h to 5 hbriefing to expanded
  • Workbook, transcript, certificateand a recorded quiz per module
  • QC, RAwho it is written for

Why ICH Q3D training matters

At a pre-approval inspection, the inspector opens your International Council for Harmonisation (ICH) Q3D risk assessment and asks where the residual solvent data is. Your team searches shared drives while the finished dose batch waits in quarantine. The launch date moves.

What changes after this course

Your analysts calculate limits from permitted daily exposures, validate gas chromatography methods and write the assessment right the first time. The file is ready before the inspector asks. You hold a certificate per learner and a per-person training record that shows who was trained.

Watch the pitch

3:43 on how an audio course is bought, listened to and recorded. Full screen, one click.

Watch the pitch3:43, full screen, one click

ICH Q3D training: what this course gives your people

Regulatory affairs stops guessing how to justify limits in the quality section of a new drug application. You apply the permitted daily exposure values from ICH Q3D to your route of administration, show the 30 percent control threshold where it applies, and send a file that does not draw a request for more safety data on elements.

In the lab, your analysts pick inductively coupled plasma mass spectrometry or another technique on the first attempt. They prepare samples so digestion errors stop creating false results. Residual solvent methods follow ICH Q2, with specificity shown and reference standards qualified, so a headspace gas chromatography run gives a number a second analyst reproduces.

When the inspector arrives, your laboratory manager hands over the three-step risk assessment and the ICH Q3C solvent classification in one folder. Questions about Class 1, 2 and 3 solvents get answered from records, not memory. Batches leave quarantine because the impurity question already has a documented answer.

Who needs ICH Q3D training

  • Quality Control Analyst

    You spot the sample preparation step that causes a false elemental result before anyone opens an out-of-specification investigation, and you set up headspace runs that repeat from one analyst to the next.

  • Regulatory Affairs Specialist

    A reviewer writes back that your elemental impurity justification lacks detail. You write the assessment summary with the permitted daily exposure, the route of administration and the reasoning already in it.

  • Quality Control Laboratory Manager

    An inspector asks for proof that your residual solvent method is valid. You hand over a validation report that shows specificity under ICH Q2 and names the qualified reference standards used.

  • Quality Assurance Specialist

    A new finished dose product arrives with a solvent list nobody has classified. You apply the ICH Q3C classes and limits in one sitting and support the batch release with the file behind you.

Roles: Regulatory affairs, Quality control and laboratory

Businesses: every kind of pharma company

Countries: India, China, Türkiye, Korea, Japan, Taiwan, Egypt, Gulf and MENA, Brazil and Latin America, Pakistan, Bangladesh and Vietnam, United States, Europe

Selling into: any jurisdiction

Courses are in English. Other languages on request.

After this course your people can

  1. Calculate an elemental impurity concentration limit from the permitted daily exposure and daily dose.
  2. Document the three-step ICH Q3D risk assessment for a finished drug product, including sources from the active ingredient, excipients and equipment.
  3. Choose between inductively coupled plasma mass spectrometry and other techniques for a named element and justify the choice in writing.
  4. Classify a residual solvent as Class 1, 2 or 3 under ICH Q3C and state the limit that applies.
  5. Set up a headspace gas chromatography method and present the specificity evidence that ICH Q2 expects.
  6. Assemble the impurity control file an inspector asks for, covering both elemental impurities and residual solvents.

What the company gets

  • Batches stop waiting in quarantine for residual solvent validation data that nobody can find.
  • New drug applications go out with an elemental impurity risk assessment that already answers the reviewer's likely questions.
  • Inspectors get one clear file that shows how your elemental impurity and residual solvent limits were set and who approved them.
  • Sample preparation follows one agreed method, so false results stop triggering out-of-specification investigations.
  • Each learner holds a certificate and a training record sits ready for the next audit.

The evidence: questionnaire, training record, certificate

EU GMP Chapter 2, section 2.11, and 21 CFR 211.25 both ask for training that is documented and shown to work. This is what each learner leaves behind.

A recorded questionnaire per module

Every one of the 6 modules ends with a multiple-choice questionnaire. The result is recorded per person with a timestamp, whichever of the three lengths the person listened to.

A per-person training record

The export lists each learner, each module, the result and the date, which is the training record EU GMP Chapter 2 and 21 CFR 211.25 ask you to keep and the first thing an inspector asks for.

A certificate per learner

Name, company, course, hours, the guideline version taught and the date. It documents in-company training; it is not a professional qualification or an accreditation.

Your pass mark, your rule

There is no fixed pass mark. Your quality or human-resources manager decides what counts as passed and when a module is retaken, exactly as your training procedure says.

Delivered within 72 hours of payment, with the workbook, the full transcript and a source for every fact in the audio.

How long it takes, by who is listening

Nobody spends a day in a classroom. Every module exists in three lengths; a person takes the length their role needs, and every length ends with the same recorded questionnaire, so the training record is complete either way.

Briefing1 h10 min a module, for executives, sales and anyone who must know the rules, not run them
Standard2 h 30 min25 min a module, for regulatory, quality and business-development staff
Expanded5 h50 min a module, for technical staff who run the procedure day to day
Who takes this courseLengthTotal time
Regulatory affairsExpanded5 h
Quality control and laboratoryExpanded5 h

ICH Q3D course outline: 6 modules

6 modules. Under each title are the three things the listener can do afterwards; the audio itself runs 10 to 50 minutes depending on the length chosen.

  1. 1Trace every ICH Q3D element from active ingredient to finished dose

    • Why an ingredient supplier's data cannot stand alone in the finished drug product assessment under ICH Q3D.
    • How to find where excipients, water and equipment add elements your active ingredient never contained.
    • What to do when a route of administration, such as inhalation, changes the limit you work to.
  2. 2Run the three-step ICH Q3D risk assessment and file it right first time

    • How to turn the permitted daily exposure for a route of administration into a limit in your own units.
    • When the 30 percent of permitted daily exposure line lets you stop adding controls, and when it does not.
    • The one-page summary that shows a reviewer why each element was in or out of your assessment.
  3. 3Match mass spectrometry and other techniques to the elements you must test

    • Why a poor sample digestion starts an out-of-specification investigation you did not need.
    • How to pick inductively coupled plasma mass spectrometry or another technique for a given element.
    • The checks for limit tests that a United States Pharmacopeia chapter 233 reviewer expects in your file.
  4. 4Classify residual solvents and set their limits under ICH Q3C

    • How to sort a solvent into Class 1, 2 or 3 and know at once what that means for your batch record.
    • What to do when a Class 1 solvent such as benzene turns up in a raw material or process step.
    • The point at which Class 3 solvents at 50 milligrams a day or less need no further justification.
  5. 5Validate gas chromatography methods for residual solvents under ICH Q2

    • How to set up headspace gas chromatography so low-level solvents show up as clear, separate peaks.
    • The specificity evidence ICH Q2 asks for, laid out so a reviewer sees it in one table.
    • Why a qualified reference standard decides whether your solvent result survives a second analyst's check.
  6. 6Defend your impurity control strategy in front of an inspector

    • How to lay out one control strategy file that answers for both elements and residual solvents.
    • Which records an inspector asks for first when an impurity result is out of specification.
    • What to say when an inspector asks who approved your limits and on what data.
The founders

One of us was inspected. The other one pays for the training.

Every claim below is sourced on the about page: the medicines register, the Lithuanian Pharmaceutical Union board list, the university directory.

Justina Krukonytė-Racz

Justina Krukonytė-Racz

Co-founder. Licensed pharmacist.

GDPResponsible PersonWarehouse & logistics

Licensed pharmacist. Responsible Person at Tamro (PHOENIX group), where she led the GDP set-up of the distribution centre.

The Responsible Person is the named person the regulator holds accountable for every pallet that leaves the building.

She writes the modules around the procedures a GDP inspection checks. Board member of Lithuanian Pharmaceutical Union.

Listed in the Lithuanian medicines register as Pharmacist.

Prof. Ben Racz

Prof. Ben Racz

Co-founder. Builds the platform and is responsible for delivery, records and pricing.

Platform & deliveryQuantitative researchCarnegie Mellon

He was Professor of the Practice at the College of Engineering at Carnegie Mellon University, where he taught Advanced Quantitative Finance and Algorithmic Trading to MSc students.

He is the founder and Managing Director of Algorithmic Sciences, a scientific research and consulting firm. Earlier he co-founded a data-driven growth consultancy, a data-science based wholesale trading company and an information security firm.

More about Ben at benracz.com

Questions about ICH Q3D training

What is an ICH Q3D risk assessment?

It is a documented evaluation of where elemental impurities could enter a finished medicine, such as the active substance, excipients, water, equipment and container closure. Each element is compared with its permitted daily exposure. ICH Q3D uses a control threshold of 30 percent of the permitted daily exposure: if levels are consistently below it, extra controls are normally not needed. Above it, the company must set controls.

How do ICH Q3C residual solvent classes work?

ICH Q3C sorts solvents into three classes. Class 1 solvents, such as benzene, should be avoided because they are known or strongly suspected carcinogens or environmental hazards. Class 2 solvents have permitted daily exposures and concentration limits because of their toxicity. Class 3 solvents have low toxic potential, and amounts up to 5000 parts per million are accepted without justification.

Is there a certificate?

Yes. Every learner who finishes the course receives a certificate in their own name, and every module ends with a recorded multiple-choice questionnaire, so the certificate sits on top of a per-person training record. The certificate documents in-company training; it is not a professional qualification or an accreditation, and your quality or human-resources manager sets the pass mark and decides when a module is retaken.

How long does the course take?

6 modules, each in three lengths: a 10-minute briefing, a 25-minute standard run and a 50-minute expanded walk-through. The whole course takes 1 h in the briefing length and 5 h in the expanded length. People take the length their role needs, and every length ends with the same recorded questionnaire, so the training record is complete either way.

Who should take this course?

It is written for QC, RA. Owners, managers and sales staff hear the briefing length, regulatory, quality and business-development staff take the standard run, and the people who run the procedure every day get the expanded version. One licence covers one named person on this course for a year, so the same title can be rolled out across a whole team at once.

Is this training accepted as a GMP training record by an auditor?

EU GMP Chapter 2 and 21 CFR 211.25 require documented, effective training, and that is what the course produces: a recorded multiple-choice result per module and per person, a certificate per learner and a transcript of what was taught. No provider can promise acceptance by a specific inspector; the record is built to answer what inspectors ask for, and your quality manager decides the pass mark.

How is it delivered and how fast?

The course arrives as audio files with a companion workbook, a full transcript and the questionnaire per module, within 72 hours of your payment arriving. You host the files on your own system or share them as you like; there is no platform to log into and no learner management system to set up. The free sample module arrives on request, before any purchase.

What does it cost per learner?

The list price is 9 euros per module, per learner, per year, so this course is 54 euros for one person for twelve months. The price per learner falls as more people take the same course: 10 learners pay 10 percent less and the discount keeps growing to 50 percent at 1000 learners. Type a number on the price panel and the yearly total appears.

Get this course for your team

One licence is one person on this course for a year. All three lengths, the workbook, the certificate and the training record are included in every purchase. Pick how many people, add it to the cart, and you have an invoice in your inbox.

Free sample module

Hear one full module before you spend a cent. Send your company and the role you want trained, and a complete sample module comes back with its workbook and transcript.

Connect on WhatsApp

or email [email protected], or ask for a written quote for your team