PharmaLectures.com

Courses › GMP, GDP, quality and compliance › Does your method actually work: analytical method validation and transfer, ICH Q2(R2) and Q14

Does your method actually work: analytical method validation and transfer, ICH Q2(R2) and Q14

Your methods validate once, transfer cleanly and release batches on schedule.

Analytical method validation is the documented demonstration that a test procedure is suitable for its intended purpose: that it measures what it claims to measure, over the right range, with known accuracy and precision. The international standard is ICH Q2(R2), adopted in November 2023 together with ICH Q14 on analytical procedure development, which replaced the long-standing Q2(R1). Method transfer is the separate exercise of proving that a second laboratory can run the validated method and get equivalent results, something Chapter 6 of the EU GMP guide requires to be planned and documented.

  • 10 audio modulesthree lengths each
  • 1 h 40 min to 8 h 20 minbriefing to expanded
  • Workbook, transcript, certificateand a recorded quiz per module
  • QCwho it is written for

Why analytical method validation training matters

The receiving lab rejects your transfer protocol, and the first batches sit in quarantine. Then an inspector asks where the specificity data for the assay is, and nobody can point to it. Weeks of validation get repeated while the release date slips.

What changes after this course

Your analysts design studies to International Council for Harmonisation (ICH) Q2(R2) and plan development under Q14 first. Reports reach quality assurance complete, and transfers meet their criteria. You hold a certificate per learner and a training record per analyst.

Watch the pitch

3:43 on how an audio course is bought, listened to and recorded. Full screen, one click.

Watch the pitch3:43, full screen, one click

Analytical method validation training: what this course gives your people

Your analysts open International Council for Harmonisation (ICH) Q2(R2) and know within minutes which characteristics their test needs. An identification test, an assay and an impurity method each get the right design. The protocol reaches quality assurance with acceptance criteria already set, and it comes back approved instead of annotated.

An inspector asks how the assay was developed. Your team hands over the analytical target profile and the risk assessment built under ICH Q14, and the answer takes one document, not a week of searching old notebooks. The development history reads as a plan, not as trial and error.

Before a method goes to a contract site, your sending lab writes a transfer protocol with criteria the receiving lab can meet. Comparative testing, co-validation or a waiver is chosen on purpose, and the reason is written down. The receiving site runs it without a deviation and starts releasing batches.

Detection and quantitation limits come out right the first time, and linearity covers the range the dossier claims. Reports go to review with the raw data attached. When a column or reagent changes, your team decides between partial and full revalidation and records the reasoning in change control.

Who needs analytical method validation training

  • Quality Control Analyst

    An inspector asks how you know the assay measures only the active ingredient. You open the validation report and point to the specificity study, run to ICH Q2(R2), with the data attached.

  • Quality Control Team Lead

    A dissolution method must move to a new testing site next quarter. You write the transfer protocol, with acceptance criteria the receiving lab meets, before anyone books instrument time.

  • Analytical Development Scientist

    You must justify the parameters of a new impurity method. You show the ICH Q14 risk assessment and the analytical target profile, and the reviewer sees a plan instead of a guess.

  • Quality Assurance Reviewer

    A validation report lands on your desk before the audit. You spot the missing intermediate precision study on the first read and send it back with a specific request.

Roles: Quality control and laboratory

Businesses: every kind of pharma company

Countries: India, China, Türkiye, Korea, Japan, Taiwan, Egypt, Gulf and MENA, Brazil and Latin America, Pakistan, Bangladesh and Vietnam, United States, Europe

Selling into: any jurisdiction

Courses are in English. Other languages on request.

After this course your people can

  1. Draft a validation protocol that sets acceptance criteria for each characteristic ICH Q2(R2) requires for the test type.
  2. Write an analytical target profile and a supporting risk assessment using ICH Q14 quality by design concepts.
  3. Calculate precision, accuracy, linearity, detection limit and quantitation limit from raw laboratory data.
  4. Choose between comparative testing, co-validation and a transfer waiver, and write the acceptance criteria for the one you pick.
  5. Decide whether a method change calls for partial or full revalidation, and record the reasoning in change control.
  6. Answer an inspector's question about your validation data by citing the report section and the raw data behind it.

What the company gets

  • Methods transfer to new sites without failed comparative testing, so batch release dates hold.
  • Inspectors receive complete validation reports that follow ICH Q2(R2) and Q14, with the raw data attached.
  • Quality assurance sees fewer protocols come back for rework and spends that time on real risks.
  • Every analyst has a certificate and a training record, so questions about competence get a document, not a debate.

The evidence: questionnaire, training record, certificate

EU GMP Chapter 2, section 2.11, and 21 CFR 211.25 both ask for training that is documented and shown to work. This is what each learner leaves behind.

A recorded questionnaire per module

Every one of the 10 modules ends with a multiple-choice questionnaire. The result is recorded per person with a timestamp, whichever of the three lengths the person listened to.

A per-person training record

The export lists each learner, each module, the result and the date, which is the training record EU GMP Chapter 2 and 21 CFR 211.25 ask you to keep and the first thing an inspector asks for.

A certificate per learner

Name, company, course, hours, the guideline version taught and the date. It documents in-company training; it is not a professional qualification or an accreditation.

Your pass mark, your rule

There is no fixed pass mark. Your quality or human-resources manager decides what counts as passed and when a module is retaken, exactly as your training procedure says.

Delivered within 72 hours of payment, with the workbook, the full transcript and a source for every fact in the audio.

How long it takes, by who is listening

Nobody spends a day in a classroom. Every module exists in three lengths; a person takes the length their role needs, and every length ends with the same recorded questionnaire, so the training record is complete either way.

Briefing1 h 40 min10 min a module, for executives, sales and anyone who must know the rules, not run them
Standard4 h 10 min25 min a module, for regulatory, quality and business-development staff
Expanded8 h 20 min50 min a module, for technical staff who run the procedure day to day
Who takes this courseLengthTotal time
Quality control and laboratoryExpanded8 h 20 min

Analytical method validation course outline: 10 modules

10 modules. Under each title are the three things the listener can do afterwards; the audio itself runs 10 to 50 minutes depending on the length chosen.

  1. 1Map International Council for Harmonisation guidelines to your daily lab work

    • How to tell in one read which guideline governs the test your analysts run today.
    • Why a gap against Q2(R2) turns into an audit observation, and where to close it first.
    • The link from Q2(R2) and Q14 to the procedures your analysts already follow, so nothing gets written twice.
  2. 2Validate your analytical procedures to ICH Q2(R2) requirements

    • Which characteristics an assay, an impurity test and an identification test each need under Q2(R2).
    • How to write a validation protocol with acceptance criteria set before the first run.
    • What to do when the guideline wording leaves a choice and the auditor asks why you made yours.
  3. 3Build methods with ICH Q14 quality by design from the first experiment

    • How to write an analytical target profile that still holds when the method reaches routine use.
    • The risk assessment that shows an auditor why you tested these parameters and not others.
    • Why a method developed under Q14 gives fewer surprises once it reaches routine testing.
  4. 4Prove specificity and set linearity across your full reporting range

    • How to design the interference experiment that proves your method sees only the analyte.
    • The way to fit and judge a linearity line so the reviewer stops asking about your residuals.
    • Why the range you choose decides which results you can report, and how to set it right.
  5. 5Calculate accuracy, precision and detection limits without rework

    • How to spike samples so recovery shows true accuracy and not a flattering baseline.
    • The difference between repeatability and intermediate precision, and the study layout for each.
    • What to do when your quantitation limit comes out above the specification you must control.
  6. 6Validate impurity quantification and dissolution methods that hold up

    • The validation characteristics a trace impurity method needs, and how to justify leaving one out.
    • How to separate real dissolution variability from method error before you set acceptance criteria.
    • Why the assay validation template fails on impurity and dissolution methods, and what to use.
  7. 7Transfer methods between labs and pass comparative testing first time

    • When to choose comparative testing, co-validation or a documented waiver for your transfer.
    • How to set transfer acceptance criteria that the receiving laboratory can actually meet.
    • The protocol gaps that make a receiving site reject a transfer, and how to close them before sending.
  8. 8Write validation reports that clear quality assurance review first time

    • What a quality assurance reviewer checks first in your report, so you answer it on page one.
    • How to record deviations during validation so they stop holding up final approval.
    • The raw data to attach so the reviewer never sends the report back for evidence.
  9. 9Decide when a changed method needs partial or full revalidation

    • When a change to column, reagent, instrument or sample preparation needs partial revalidation, and when not to.
    • How to use ongoing performance monitoring to catch a drifting method before it fails a batch.
    • The change control record that shows why you revalidated in part, or why you did not at all.
  10. 10Answer inspector questions about your validation data on the spot

    • What to do when an inspector challenges your linearity data in front of the whole team.
    • The validation deficiencies inspectors cite most, so you can check your own files before they do.
    • Why a complete training record closes the question of analyst competence before it is asked.
The founders

One of us was inspected. The other one pays for the training.

Every claim below is sourced on the about page: the medicines register, the Lithuanian Pharmaceutical Union board list, the university directory.

Justina Krukonytė-Racz

Justina Krukonytė-Racz

Co-founder. Licensed pharmacist.

GDPResponsible PersonWarehouse & logistics

Licensed pharmacist. Responsible Person at Tamro (PHOENIX group), where she led the GDP set-up of the distribution centre.

The Responsible Person is the named person the regulator holds accountable for every pallet that leaves the building.

She writes the modules around the procedures a GDP inspection checks. Board member of Lithuanian Pharmaceutical Union.

Listed in the Lithuanian medicines register as Pharmacist.

Prof. Ben Racz

Prof. Ben Racz

Co-founder. Builds the platform and is responsible for delivery, records and pricing.

Platform & deliveryQuantitative researchCarnegie Mellon

He was Professor of the Practice at the College of Engineering at Carnegie Mellon University, where he taught Advanced Quantitative Finance and Algorithmic Trading to MSc students.

He is the founder and Managing Director of Algorithmic Sciences, a scientific research and consulting firm. Earlier he co-founded a data-driven growth consultancy, a data-science based wholesale trading company and an information security firm.

More about Ben at benracz.com

Questions about analytical method validation training

What is ICH Q2(R2)?

ICH Q2(R2) is the revised International Council for Harmonisation guideline on validation of analytical procedures, reaching final adoption in November 2023 alongside ICH Q14. It keeps the familiar performance characteristics, specificity, range, accuracy and precision, but frames them around the intended purpose of the procedure, covers newer techniques such as spectroscopic and multivariate methods, and links validation to the life cycle approach in Q14.

What is the difference between method validation and method transfer?

Validation proves the method itself works for its purpose, usually in the laboratory that developed it, and produces the data ICH Q2(R2) describes. Transfer proves that another laboratory, a contract testing site or your customer in Europe, can run that same method and get comparable results on the same samples. EU GMP Chapter 6 requires a transfer protocol, defined acceptance criteria and a report before the receiving laboratory tests for release.

Is there a certificate?

Yes. Every learner who finishes the course receives a certificate in their own name, and every module ends with a recorded multiple-choice questionnaire, so the certificate sits on top of a per-person training record. The certificate documents in-company training; it is not a professional qualification or an accreditation, and your quality or human-resources manager sets the pass mark and decides when a module is retaken.

How long does the course take?

10 modules, each in three lengths: a 10-minute briefing, a 25-minute standard run and a 50-minute expanded walk-through. The whole course takes 1 h 40 min in the briefing length and 8 h 20 min in the expanded length. People take the length their role needs, and every length ends with the same recorded questionnaire, so the training record is complete either way.

Who should take this course?

It is written for QC. Owners, managers and sales staff hear the briefing length, regulatory, quality and business-development staff take the standard run, and the people who run the procedure every day get the expanded version. One licence covers one named person on this course for a year, so the same title can be rolled out across a whole team at once.

Is this training accepted as a GMP training record by an auditor?

EU GMP Chapter 2 and 21 CFR 211.25 require documented, effective training, and that is what the course produces: a recorded multiple-choice result per module and per person, a certificate per learner and a transcript of what was taught. No provider can promise acceptance by a specific inspector; the record is built to answer what inspectors ask for, and your quality manager decides the pass mark.

How is it delivered and how fast?

The course arrives as audio files with a companion workbook, a full transcript and the questionnaire per module, within 72 hours of your payment arriving. You host the files on your own system or share them as you like; there is no platform to log into and no learner management system to set up. The free sample module arrives on request, before any purchase.

What does it cost per learner?

The list price is 9 euros per module, per learner, per year, so this course is 90 euros for one person for twelve months. The price per learner falls as more people take the same course: 10 learners pay 10 percent less and the discount keeps growing to 50 percent at 1000 learners. Type a number on the price panel and the yearly total appears.

Get this course for your team

One licence is one person on this course for a year. All three lengths, the workbook, the certificate and the training record are included in every purchase. Pick how many people, add it to the cart, and you have an invoice in your inbox.

Free sample module

Hear one full module before you spend a cent. Send your company and the role you want trained, and a complete sample module comes back with its workbook and transcript.

Connect on WhatsApp

or email [email protected], or ask for a written quote for your team